SARBUZ SBX Series

0,00 

Evaporator Coil
> Copper tubes Ø1/2”, Ø5/8”,
> Fins made of aluminium,
> Fin spacings are 12 mm,
> Header inlet and outlet tube connections made of copper,
> Admissible pressure Ps=24 Bar.

Casing
> Galvanized steel sheet painted to RAL 9016 (traffic white)
> Insulated drip tray,

Fans
> Low-noise axial fans with maintenance free motors,
> Protection class IP 54, three phase 400V 3~ 50Hz fan,
> Constructions insulation material class F, admissible temperature -40°C up to +60°C,
> In case of long periods of non operation the motors must be operated every month for 2 hours,
> The integral thermo contacts (thermistors) must be used as motor protection,
> At low ambient temperatures and different air resistance the power consumption will increase.

Sound Specifications
> The sound pressure levels are calculated according to EN 13487.

Defrosting

> Electrical defrost,

Capacity
> The nominal capacities calculated according to Eurovent (EN 328) standards that refer to SC5 condition and are valid for R404A,
> The refrigerating capacities refer to an air inlet temperature difference which results from the difference between cooler air inlet temperature Tr, evaporating temperature Te and ΔT = Tr – Te.

More information is available at the link below:

http://www.sarbuz.com/2/74/76/sbx_serie/87/detay

Out of stock

SKU: 06718 Category:

Description

Evaporator Coil
> Copper tubes Ø1/2”, Ø5/8”,
> Fins made of aluminium,
> Fin spacings are 12 mm,
> Header inlet and outlet tube connections made of copper,
> Admissible pressure Ps=24 Bar.

Casing
> Galvanized steel sheet painted to RAL 9016 (traffic white)
> Insulated drip tray,

Fans
> Low-noise axial fans with maintenance free motors,
> Protection class IP 54, three phase 400V 3~ 50Hz fan,
> Constructions insulation material class F, admissible temperature -40°C up to +60°C,
> In case of long periods of non operation the motors must be operated every month for 2 hours,
> The integral thermo contacts (thermistors) must be used as motor protection,
> At low ambient temperatures and different air resistance the power consumption will increase.

Sound Specifications
> The sound pressure levels are calculated according to EN 13487.

Defrosting

> Electrical defrost,

Capacity
> The nominal capacities calculated according to Eurovent (EN 328) standards that refer to SC5 condition and are valid for R404A,
> The refrigerating capacities refer to an air inlet temperature difference which results from the difference between cooler air inlet temperature Tr, evaporating temperature Te and ΔT = Tr – Te.

Additional information

Producer

Type

Model