Technical Specifications: 

Power – 1.2 kW
Tube current: 2 -15 mA
Frequency: 140 kHz
Input voltage(AC):100 -240 V 50/60 Hz
Tube focal spot: 0.7 mm with X-ray tube OPX110 / 0.6 mm with X-ray tube D-067
Total filtration: > 2.5 mm eq. Al
Minimum required space:
Without cepharm: 1200 (L) x 1400 (D) x 2400 (H) mm
With cepharm: 2000 (L) x 1400 (D) x 2400 (H) mm
Weight:
Without cepharm: 92 kg (202 lb.)
With cepharm: 127 kg (280lb.)
Gray scale: 16384 -14 bits
Exposure mode: High Definition (75 µm), Standard, Fast and low dose
Exposure time: 3 to 20 sec
Image field: Field of View (cm): 4 x 4 / 5 x 5 8 x 5 / 8 x 8 / 8 x 9 / 12 x 5 / 12 x 10
Magnification: 1.13
Radiological exam options: Full, upper or lower jaw -Full, upper or lower molar – Occlusion -Teeth

Certificate of Origin

Certificate_EU QMS

 

Dental x-ray 3D device CS9600

Maximum absorbed power: 2.2 kVA
Nominal high voltage: 120 kV
Maximum corresponding tube current: 8 mA
Maximum corresponding high voltage: 80 kV

Input voltage: 100-240 V – 50/60 Hz
dimensions: 1284 (L) x 1669 (D) x 2526 mm (H)
Weight: 210 kg
X-ray Generator:
Tube voltage: 60 – 90 kV
Tube current: 2 – 15 mA
Frequency: 140 kHz
Total filtration: > 2.5 mm eq. AL
Weight: 8.2 kg
Dimensions: 235 x 245 x 120 mm

Out of stock

SKU: 08879 Category:

Description

www.carestreamdental.com/en-us/csd-products/extraoral-imaging/cbct3d-imaging/cs-8200-3d/

Dental X-ray unit

CS 8200 3D

Technical Specifications: 

Power – 1.2 kW
Tube current: 2 -15 mA
Frequency: 140 kHz
Input voltage(AC):100 -240 V 50/60 Hz
Tube focal spot: 0.7 mm with X-ray tube OPX110 / 0.6 mm with X-ray tube D-067
Total filtration: > 2.5 mm eq. Al
Minimum required space:
Without cepharm: 1200 (L) x 1400 (D) x 2400 (H) mm
With cepharm: 2000 (L) x 1400 (D) x 2400 (H) mm
Weight:
Without cepharm: 92 kg (202 lb.)
With cepharm: 127 kg (280lb.)
Gray scale: 16384 -14 bits
Exposure mode: High Definition (75 µm), Standard, Fast and low dose
Exposure time: 3 to 20 sec
Image field: Field of View (cm): 4 x 4 / 5 x 5 8 x 5 / 8 x 8 / 8 x 9 / 12 x 5 / 12 x 10
Magnification: 1.13
Radiological exam options: Full, upper or lower jaw -Full, upper or lower molar – Occlusion -Teeth

Certificate of Origin

Certificate_EU QMS

 

Dental x-ray 3D device CS9600

Maximum absorbed power: 2.2 kVA
Nominal high voltage: 120 kV
Maximum corresponding tube current: 8 mA
Maximum corresponding high voltage: 80 kV

Input voltage: 100-240 V – 50/60 Hz
dimensions: 1284 (L) x 1669 (D) x 2526 mm (H)
Weight: 210 kg
X-ray Generator:
Tube voltage: 60 – 90 kV
Tube current: 2 – 15 mA
Frequency: 140 kHz
Total filtration: > 2.5 mm eq. AL
Weight: 8.2 kg
Dimensions: 235 x 245 x 120 mm