RCF – 240W 6 ZONES POWERED MASTER UNIT – CFMZM2124

https://www.rcf.it/

RCF – 240W 6 ZONES POWERED MASTER UNIT – CFMZM2124 – Background music and sound announcement system with accessories.

• Dual-bus system architecture
• System Paging consoles input for up to 6 selective devices daisy-chained, aux input and overall emergency input on precedence primary bus
• 4 inputs of which 2 microphone and 2 universal, 3 selectable aux inputs with individual volume and tone controls with configurable priority on secondary bus
• 240W constant voltage power amplifier with VU-meter for output signal level and overload indication.
• Auxiliary external amplifier input and output terminals to manage primary and secondary buses independently
• Volume attenuators and switches with indicators to send or not the secondary bus program (i.e. music) on each of the 6 speaker line outputs
• Link to connect up to eight CFMZE2200 6six-zone expansion units so to built-up paging systems in excess of 50 zones.
• Dedicated wall mounting system remote control allows you to remote the main commands available on the master unit
• Priority indicator to show when any system priority circuit has been triggered
• Selectable chime generator is available on announcements
• GPI and GPO logic ports are available for interface purposes with third parties systems and for monitoring feedback

INTERNAL AMPLIFIER MAX. OUTPUT POWER – 240 W
INTERNAL AMPLIFIER OUTPUT VOLTAGE 100 – 70 V (direct), 100 V (6 zones)
FREQUENCY RESPONSE (+1 / -3 dB) – MIC: 60 Hz ÷ 15 kHz ; AUX: 50 Hz ÷ 20 kHz
DISTORTION – < 1%
INPUT SENSITIVITY MIC/LINE/AUX – 1,5 mV (– 54 dBu) / 200 mV (– 12 dBu) / 200 mV (– 12 dBu)
NOISE/SIGNAL RATIO INPUT MIC/LINE/AUX – > 60 dB / > 70 dB / > 75 dB
INPUT IMPEDANCE MIC/LINE/AUX – 600 Ω (balanced) / 600 Ω (balanced) / 10 kΩ (unbalanced)
INPUTS – 4 input mic. + 3 aux su RCA + 2 paging
OUTPUTS – 6 (power)
EMERGENCY INPUT SENSITIVITY – 100 mV (unbalanced audio signal), 100 V line
SIGNAL/NOISE RATIO EMERGENCY INPUT – > 70 dB
EMERGENCY INPUT IMPEDANCE – 600 Ω (balanced audio signal, input 100 mV)
POWER SUPPLY – 115 V / 230 V ac, 24 V dc
MAX POWER CONSUMPTION – 720 W

Accessories:

• 6-zone announcement microphone
• Remote control panel
• 6” 6W ceiling speaker
• Dynamics ceiling adapter
• 5,5” 6W plastic speaker
• 2 ways 3,5” + 1” 15W IP55 compact speaker
• Fire Ressistant Cables
• Lan Cables

SPECSHEET-ENG-ZM 2124

SPECSHEET-FRA-RC 2946

SPECSHEET-ITA-BM 2006

SPECSHEET-ITA-DUP 5EN

SPECSHEET-ITA-PL 60

SPECSHEET-ENG-DM 41

SKU: 08486 Category:

Description

https://www.rcf.it/

RCF – 240W 6 ZONES POWERED MASTER UNIT – CFMZM2124 – Background music and sound announcement system with accessories.

• Dual-bus system architecture
• System Paging consoles input for up to 6 selective devices daisy-chained, aux input and overall emergency input on precedence primary bus
• 4 inputs of which 2 microphone and 2 universal, 3 selectable aux inputs with individual volume and tone controls with configurable priority on secondary bus
• 240W constant voltage power amplifier with VU-meter for output signal level and overload indication.
• Auxiliary external amplifier input and output terminals to manage primary and secondary buses independently
• Volume attenuators and switches with indicators to send or not the secondary bus program (i.e. music) on each of the 6 speaker line outputs
• Link to connect up to eight CFMZE2200 6six-zone expansion units so to built-up paging systems in excess of 50 zones.
• Dedicated wall mounting system remote control allows you to remote the main commands available on the master unit
• Priority indicator to show when any system priority circuit has been triggered
• Selectable chime generator is available on announcements
• GPI and GPO logic ports are available for interface purposes with third parties systems and for monitoring feedback

INTERNAL AMPLIFIER MAX. OUTPUT POWER – 240 W
INTERNAL AMPLIFIER OUTPUT VOLTAGE 100 – 70 V (direct), 100 V (6 zones)
FREQUENCY RESPONSE (+1 / -3 dB) – MIC: 60 Hz ÷ 15 kHz ; AUX: 50 Hz ÷ 20 kHz
DISTORTION – < 1%
INPUT SENSITIVITY MIC/LINE/AUX – 1,5 mV (– 54 dBu) / 200 mV (– 12 dBu) / 200 mV (– 12 dBu)
NOISE/SIGNAL RATIO INPUT MIC/LINE/AUX – > 60 dB / > 70 dB / > 75 dB
INPUT IMPEDANCE MIC/LINE/AUX – 600 Ω (balanced) / 600 Ω (balanced) / 10 kΩ (unbalanced)
INPUTS – 4 input mic. + 3 aux su RCA + 2 paging
OUTPUTS – 6 (power)
EMERGENCY INPUT SENSITIVITY – 100 mV (unbalanced audio signal), 100 V line
SIGNAL/NOISE RATIO EMERGENCY INPUT – > 70 dB
EMERGENCY INPUT IMPEDANCE – 600 Ω (balanced audio signal, input 100 mV)
POWER SUPPLY – 115 V / 230 V ac, 24 V dc
MAX POWER CONSUMPTION – 720 W

Accessories:

• 6-zone announcement microphone
• Remote control panel
• 6” 6W ceiling speaker
• Dynamics ceiling adapter
• 5,5” 6W plastic speaker
• 2 ways 3,5” + 1” 15W IP55 compact speaker
• Fire Ressistant Cables
• Lan Cables

SPECSHEET-ENG-ZM 2124

SPECSHEET-FRA-RC 2946